TC-3400 PID Temperature Control
Input Voltage: 85 - 264 VAC, 12-40 VDC
Environment: -18 - 65 °C operating temprature, 0 - 90 percent RH, none-condensing
Agency /approvals: UL®/EN 61010 listed, UL® 1604 Class 1 Div 2, UL® 50 N |
The TC-3400 temperature controller series simplifies your temperature control requirements.
The controller options reduce system complexity and the cost of control loop ownership.
The TC-3400 is a high performance PID temperature controller in space-saving, panel-mount 1/32 DIN size EIA 485 communications and standard NEMA-4X IP66 sealing make the TC-3400 versatile and suitable for wide range of environments. |
Build your own TC-3400 part number to meet your application requirments:
|
|
|
34 |
- |
X |
|
X |
|
X |
- |
X |
|
X |
- |
X |
X |
X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
Universal AC - 85 to 264 VAC, 47 to 63 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
12/24 VDC - 12 to 40 VDC, 20 to 28 VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Functions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
Heat/Cool -No relay |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
Cool only, with relays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
Heat/Cool, with relays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Switching Volts & Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
None, drive signal only - no relays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
Cool only, VAC switching, 120/240Vac, 10 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C |
Cool Only, VDC switching, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D |
Cool Only, VDC switching, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E |
Cool Only, VDC switching, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F |
Heat/Cool, VDC switching, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G |
Heat/Cool, VDC switching, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H |
Heat/Cool, VDC switching, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I |
Heat/Cool, Heat: 120/240 VAC, 10 amps Cool: VDC switching, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
J |
Heat/Cool, Heat: 120/240 VAC, 10 amps Cool: VDC switching, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K |
Heat/Cool, Heat: 120/240 VAC, 10 amps Cool: VDC switching, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L |
Heat/Cool, Heat: 0-100 VDC, 12 Amps Cool: VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M |
Heat/Cool, Heat: 0-100 VDC, 20 Amps Cool: VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N |
Heat/Cool, Heat: 0-100 VDC, 40 Amps Cool: VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
O |
Heat/Cool, Reverse Polarity, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P |
Heat/Cool, Reverse Polarity, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Q |
Heat/Cool, Reverse Polarity, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R |
Heat/Cool, VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sensor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
None |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
3- Wire RTD - RTD-Probe |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
T type thermocouple (ring mount) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Communications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
Basic communications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
RS-232 external option, same as 2 with addition of RS-232/RS-485 converter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
RS-485 internal option, full feature communication |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Custom Features |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Click on the image for larger view
Click on the image for largr view
Click on the images to open the PDF files
|