Through Mounted Air Conditioners For Hazardous Locations
The enclosure air conditioners on this page are suitable for hazardous environments, designed for cooling C1D2 and C1D1 enclosures.
All are through-mounted. ... read more ➡ |
|
AHP-1800XP Series
Mounting Style: Through Mounted
Voltages: 120, 120/240 VAC
Environments: Class I Div 2, NEMA-4X IP56
Agency Approvals: UL-1604, UL-1995/CSA 22.2
ETL |
Rating Traditional:
1100 BTU/hr @ 0 °F ΔT
1420 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
322 Watts L35 L35
210 Watts L35 L50 |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC (VDC) |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
APPROVALS (NRTL) |
AHP-1800XP |
0-0180-2-002 |
1035-1180 |
120 |
8 |
TC-6F |
-40/+75 |
-10/+60 |
Yes |
AHP-1800XP |
0-01F0-2-002 |
1035-1180 |
120 |
8 |
85°F (30°C) |
-40/+75 |
-10/+60 |
Yes |
AHP-1800XP-1 |
0-0170-2-004 |
1035-1180 |
120 |
8 |
EXT |
-40/+75 |
-10/+60 |
Yes |
AHP-1800XPHC |
0-0130-3-003 |
1035-1180 |
120 |
8 |
TC-3F |
-40/+75 |
-10/+60 |
Yes |
AHP-1800XPHC-1 |
0-0170-3-006 |
1035-1180 |
120 |
8 |
EXT |
-40/+75 |
-10/+60 |
Yes |
AHP-1801XP |
0-0181-2-002 |
1035-1180 |
120/240 |
8.0/5.0 |
TC-6F |
-40/+75 |
-10/+60 |
Yes |
AHP-1801XP |
0-01F1-2-002 |
1035-1180 |
120/240 |
8.0/5.0 |
85°F (30°C) |
-40/+75 |
-10/+60 |
Yes |
AHP-1801XP-1 |
0-0171-2-005 |
1035-1180 |
120/240 |
8.0/5.0 |
EXT |
-40/+75 |
-10/+60 |
Yes |
AHP-1801XPHC |
0-0131-3-003 |
1035-1180 |
120/240 |
8.0/5.0 |
TC-3F |
-40/+75 |
-10/+60 |
Yes |
AHP-1801XPHC-1 |
0-0171-3-004 |
1035-1180 |
120/240 |
8.0/5.0 |
EXT |
-40/+75 |
-10/+60 |
Yes |
EXT: Unit is set up for 5-32 VDC external signal, relay(s) include
Click on the image for a larger view
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the images to open the PDF files
|
|
|
AHP-1800EP Series
Mounting Style: Through Mounted
Voltages: 120, 120/240 VAC
Environments: Class I Div 2, NEMA-12 IP52
Agency Approvals: UL-1604, UL-1995/CSA 22.2
ETL |
Rating Traditional:
1100 BTU/hr @ 0 °F ΔT
1420 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
322 Watts L35 L35
210 Watts L35 L50 |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC (VDC) |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
APPROVALS (NRTL) |
AHP-1800EP |
0-0180-0-002 |
1035-1180 |
120 |
8 |
TC-6F |
-40/+63 |
-10/+60 |
Yes |
AHP-1800EP |
0-01F0-0-002 |
1035-1180 |
120 |
8 |
85°F (30°C) |
-40/+63 |
-10/+60 |
Yes |
AHP-1800EP-1 |
0-0170-0-004 |
1035-1180 |
120 |
8 |
EXT |
-40/+63 |
-10/+60 |
Yes |
AHP-1800EPHC |
0-0130-1-003 |
1035-1180 |
120 |
8 |
TC-3F |
-40/+63 |
-10/+60 |
Yes |
AHP-1800EPHC-1 |
0-0170-1-006 |
1035-1180 |
120 |
8 |
EXT |
-40/+63 |
-10/+60 |
Yes |
AHP-1801EP |
0-0181-0-002 |
1035-1180 |
120/240 |
8.0/5.0 |
TC-6F |
-40/+63 |
-10/+60 |
Yes |
AHP-1801EP |
0-01F1-0-002 |
1035-1180 |
120/240 |
8.0/5.0 |
85°F (30°C) |
-40/+63 |
-10/+60 |
Yes |
AHP-1801EP-1 |
0-0171-0-002 |
1035-1180 |
120/240 |
8.0/5.0 |
EXT |
-40/+63 |
-10/+60 |
Yes |
AHP-1801EPHC |
0-0131-1-003 |
1035-1180 |
120/240 |
8.0/5.0 |
TC-3F |
-40/+63 |
-10/+60 |
Yes |
AHP-1801EPHC-1 |
0-0131-1-006 |
1035-1180 |
120/240 |
8.0/5.0 |
EXT |
-40/+63 |
-10/+60 |
Yes |
EXT*:
Unit is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to open the PDF fil
|
|
|
AHP-1802XP Series
Mounting Style: Through Mounted
Voltages: 240 VAC
Environments: IP54 Zone 1, Zone 2, Ex II 2 G, T1 - T3
Agency approvals: This product has not been tested by a testing agency. |
Rating Traditional:
940 BTU/hr @ 0 °F ΔT
1210 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
280 Watts L35 L35
160 Watts L35 L50 |
Click on part number to request a quick quote
MODEL NUMBER
|
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
CURRENT
AMPS. |
TEMP.
CONTROL |
OPERATING
Ambient °C MAX |
AHP-1802XP |
0-0182-2-007 |
Cool only |
240 |
5.3 |
TC-6F |
50 |
AHP-1802XP |
0-0172-2-009 |
Cool only |
240 |
5.3 |
EXT |
50 |
AHP-1802XPHC |
0-0132-3-008 |
Heat/Cool |
240 |
5.3 |
TC-3F |
50 |
AHP-1802XPHC |
0-0172-3-010 |
Heat/Cool |
240 |
5.3 |
EXT |
50
|
EXT*:
Unit is set up for 5-32 VDC external signal, relay(s) included
Click on the images for larger view
Click on the image for a larger view
View or request 3D solid model files for this product:
Clic on the image to open the PDF file
|
|
|
AHP-1200XP Series
Mounting Style: Through Mounted
Voltages: 120, 120/240 VAC
Environments: Class I Div 2, NEMA-4X IP56
Agency Approvals: UL-1604, UL-1995/CSA 22.2
ETL |
Rating Traditional:
530 BTU/hr @ 0 °F ΔT
670 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
154 Watts L35 L35
100 Watts L35 L50 |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
APPROVALS (NRTL) |
AHP-1200XP |
0-3080-2-003 |
500-550 |
120 |
4 |
TC-6F |
-40/+71 |
-10/+60 |
Yes |
AHP-1200XP |
0-30F0-2-004 |
500-550 |
120 |
4 |
85°F (30°C) |
-40/+71 |
-10/+60 |
Yes |
AHP-1200XP-1 |
0-3070-2-010 |
500-550 |
120 |
4 |
EXT |
-40/+71 |
-10/+60 |
Yes |
AHP-1200XPHC |
0-3030-3-007 |
500-550 |
120 |
4 |
TC-3F |
-40/+71 |
-10/+60 |
Yes |
AHP-1200XPHC-1 |
0-3070-3-009 |
500-550 |
120 |
4 |
EXT |
-40/+71 |
-10/+60 |
Yes |
AHP-1201XP |
0-3081-2-014 |
500-550 |
120/240 |
4.0/2.0 |
TC-6F |
-40/+71 |
-10/+60 |
Yes |
AHP-1201XP |
0-30F1-2-020 |
500-550 |
120/240 |
4.0/2.0 |
85°F (30°C) |
-40/+71 |
-10/+60 |
Yes |
AHP-1201XP-1 |
0-3071-2-012 |
500-550 |
120/240 |
4.0/2.0 |
EXT |
-40/+71 |
-10/+60 |
Yes |
AHP-1201XPHC |
0-3031-3-011 |
500-550 |
120/240 |
4.0/2.0 |
TC-3F |
-40/+71 |
-10/+60 |
Yes |
AHP-1201XPHC-1 |
0-3071-3-013 |
500-550 |
120/240 |
4.0/2.0 |
EXT |
-40/+71 |
-10/+60 |
Yes |
EXT: Unit is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the imge to open the PDF file
-570
|
|
|
|
AHP-1200EP Series
Mounting Style: Through Mounted
Voltages: 120, 120/240 VAC
Environments: Class I Div 2, NEMA-12 IP52
Agency Approvals: UL-1604, UL-1995/CSA 22.2
ETL |
Rating Traditional:
210 BTU/hr @ 0 °F ΔT
250 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
61 Watts L35 L35
44 Watts L35 L50 |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
APPROVALS (NRTL) |
AHP-1200EP |
0-3080-0-003 |
500-550 |
120 |
4 |
TC-6F |
-40/+63 |
-10/+60 |
Yes |
AHP-1200EP |
0-30F0-0-004 |
500-550 |
120 |
4 |
85°F (30°C) |
-40/+63 |
-10/+60 |
Yes |
AHP-1200EP-1 |
0-3070-0-010 |
500-550 |
120 |
4 |
EXT |
-40/+63 |
-10/+60 |
Yes |
AHP-1200EPHC |
0-3030-1-007 |
500-550 |
120 |
4 |
TC-3F |
-40/+63 |
-10/+60 |
Yes |
AHP-1200EPHC-1 |
0-3070-1-009 |
500-550 |
120 |
4 |
EXT |
-40/+63 |
-10/+60 |
Yes |
AHP-1201EP |
0-3081-0-003 |
500-550 |
120/240 |
4.0/2.0 |
TC-6F |
-40/+63 |
-10/+60 |
Yes |
AHP-1201EP |
0-30F1-0-004 |
500-550 |
120/240 |
4.0/2.0 |
85°F (30°C) |
-40/+63 |
-10/+60 |
Yes |
AHP-1201EP-1 |
0-3071-0-010 |
500-550 |
120/240 |
4.0/2.0 |
EXT |
-40/+63 |
-10/+60 |
Yes |
AHP-1201EPHC |
0-3031-1-007 |
500-550 |
120/240 |
4.0/2.0 |
TC-3F |
-40/+63 |
-10/+60 |
Yes |
AHP-1201EPHC-1 |
0-3071-1-009 |
500-550 |
120/240 |
4.0/2.0 |
EXT |
-40/+63 |
-10/+60 |
Yes |
EXT: Unit is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to open the PDF file
-570
|
|
|
|
AHP-1200CXP Series
Mounting Style: Through Mounted
Voltages: 120 VAC
Environments: Class I Division 1, Groups B, C, D
NEMA-4X IP56 |
Rating Traditional:
307-680 BTU/hr @ 0 °F ΔT
Rating DIN 3168:
61 Watts L35 L35
44 Watts L35 L50
|
As an integral part of a larger system AHP-1200CXP has been investigated in accordance with UL 3111-1, first Edition, Rev. 6/94 Electrical Equipment for laboratory use and CSA C22.2 No. 1010.1-92 Safety Requirments for Electrical Equipment for Measurment, Control and Laboratory use.
As an integral part of a larger system it has been investigated in accordance with NFPA 496 Edition Purged and Pressurized Enclosure for Electrical Equipment. |
Click on part number to request a quick quote
MODEL NUMBER
|
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
CURRENT
AMPS. |
TEMP.
CONTROL |
AMBIENT
RANGE
°C |
APPROVALS (NRTL) |
AHP-1200CXP |
0-3070-2-016 |
Cool only |
120 |
4.0 |
EXT |
-20/40 |
See notes |
EXT: Unit is set up for 5-32 VDC external signal, relay(s) included
Requirments:
- Clean and dry compressed air supply
- Purged enclosure
- 120 VAC input voltage
- Temperature control
As an integral part of a larger system AHP-1200CXP has been investigated in accordance with UL 3111-1, first Edition, Rev. 6/94 Electrical Equipment for laboratory use and CSA C22.2 No. 1010.1-92 Safety Requirments for Electrical Equipment for Measurment, Control and Laboratory use.
As an integral part of a larger system it has been investigated in accordance with NFPA 496 Edition Purged and Pressurized Enclosure for Electrical Equipment.
Click on the images for larger view
Click on the images for larger views
25C ambient performance curve
|
60C ambient performance curve
|
Click on the image for larger view
View or request 3D solid model files for this product:
Click on the images to open the PDF files
|
|
|
AHP-1200CXP Series
Mounting Style: Through Mounted
Voltages: 120 VAC
Environments:Zone 1, Group II, Catagory 2 [1] G
EEx p d [ia] ia IIB+H2 T4, IP56 |
Rating DIN 3168:
307-680 BTU/hr @ 0 °F ΔT |
The AHP-1200CXP is TECA’s first solid state air conditioner designed for use in hazardous environments in the United Kingdom and European Union. The AHP-1200CXP features a unique air moving device that eliminates static discharge that traditional fans can generate. A compressed air line is required for the air moving device. The AHP-1200CXP has been successfully implemented
with a purged enclosure and other approved equipment in pharmaceutical, petrochemical and other similar applications.
Directive 94/9/EC with reference to EN50014:1997/A2:1999, EN50016:2002.
Procedure XF011, XF013
Group II, Category 2 [1] G EEx p d [ia] ia IIB+H2 T4 Ta=-20 °C to +40 |
Click on part number to request a quick quote
MODEL NUMBER
|
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
CURRENT
AMPS. |
TEMP.
CONTROL |
AMBIENT
RANGE
°C |
APPROVALS (NRTL) |
AHP-1200CXP |
0-3070-2-018 |
Cool only |
120 |
4.0 |
EXT |
-20/40 |
See notes |
EXT: Unit is set up for 5-32 VDC external signal, relay(s) included
Requirments:
- Clean and dry compressed air supply
- Purged enclosure
- 120 VAC input voltage
- Temperature control
The AHP-1200CXP is TECA’s first solid state air conditioner designed for use in hazardous environments in the United Kingdom and European Union. The AHP-1200CXP features a unique air moving device that eliminates static discharge that traditional fans can generate. A compressed air line is required for the air moving device. The AHP-1200CXP has been successfully implemented
with a purged enclosure and other approved equipment in pharmaceutical, petrochemical and other similar applications.
Directive 94/9/EC with reference to EN50014:1997/A2:1999, EN50016:2002.
Procedure XF011, XF013
Group II, Category 2 [1] G EEx p d [ia] ia IIB+H2 T4 Ta=-20 °C to +4
Click on the images for larger view
Click on the images for larger views
25C ambient performance curve
|
60C ambient performance curve
|
Click on the image for larger view
View or request 3D solid model files for this product:
Click on the images to open the PDF files
|
|
The “XP” and "CXP" thermoelectric air conditioners are designed for cooling Class I Division 2 (C1D2) and Class I Division 1 (C1D1) enclosures, respectively. The products on this page are all through-mounted. The internal side or “cold side” of the cabinet air conditioner will intrude into your enclosure, leaving the external side or “hot side” outside of your cabinet. Mounting gasket and hardware are always included.
TECA’s thermoelectric (Peltier) air conditioners for thermal control of C1D2 and C1D1 enclosures excel in these hazardous environments and high ambients. Built with mil-spec hot side fans the Class I Division 2 "XP" air conditioner models can be exposed to hazardous environments as well as rain, wash-down, salt spray, blowing sand and shock per Mil-Std 810 (Shock & Corrosion) and the NEMA-4/4X environment rating. Our Peltier air conditioners are often used for cooling electrical enclosures/panels in applications including COTS, shipboards, military communications, mobile military units, manufacturing facilities, laboratories, and more.
TECA's thermoelectric Class I Division 1 "CXP" enclosure coolers are the first solid state air conditoners designed for use in Class 1 Division 1 (Groups B, C and D) and hazardous environments in Noth America and the U.K./European Union, respectively. The "CXP" air conditioner models feature a unique air moving device that eliminates the static discharge that traditional fans can generate. A compressed air line is required for the air moving device. The "CXP" products have been used in pharmaceutical and petrochemical thermostat control applications.
The solid-state construction is the perfect low-maintenance solution for cooling hard-to-access industrial enclosures. There are no filters to change and no moving parts except for the fans. Our thermoelectric industrial enclosure coolers use robust thermoelectric modules and boast a long service life. |
|
|
|
|
|
|
|
|
|